DTRO Membrane Cleaning
- Aug 31, 2018 -

DTRO membrane cleaning


DTRO membrane cleaning includes both rinsing and chemical cleaning.


The reverse osmosis system has a cleaning agent A, a cleaning agent C, a scale inhibitor and a cleaning buffer tank. The operator needs to regularly add cleaning agent and scale inhibitor to the tank to set the cleaning execution time. The system automatically executes when cleaning is required.


System flushing:


The flushing of the membrane group is carried out every time the system is shut down. When it is necessary to stop in the normal startup state, the flushing mode is generally followed by the shutdown mode. The system automatically stops when the system fails, and the flushing program is also executed. The main purpose of rinsing is to prevent contaminants in the raw water from depositing on the surface of the diaphragm. There are two types of flushing, one is flushing with raw water, and the other is flushing with clean water. The time of both flushing can be set on the operation interface, usually 2-5 minutes.